PXI Microwave Switch Module DC-26.5GHz Agilent M9157C

Code: Agilent M9157C


 

Datasheet PDF, 1.06 Mb

Description

  • Hybrid Single SP6T Switch Terminated
  • 0.03 dB insertion loss repeatability guaranteed throughout the 2 million cycle operating life, ensures accuracy of your test results
  • Unmatched isolation 90 dB at 12 GHz minimizes cross talk in high density ATE systems
  • Broadband from DC to 26.5 GHz fits most communication and aerospace/defense applications
  • Route RF and microwave signals in automated test applications
  • Flexibility to build switch matrix as desired, hence a low cost solution
  • Peace of mind in switch technology from Agilent who has a proven record for providing versatile, quality switches
  • Exceptional 0.03 dB insertion loss repeatability
  • Long life cycles - 2 million cycles guaranteed, 5 million cycles typical
  • Unmatched isolation and low SWR
 

More products KEYSIGHT

AGILENT N9320A RF SPECTRUM ANALYZER 9 KHZ..3 GHZ

• 9 kHz to 3 GHz Frequency range
• 10 Hz to 1 MHz RBW
• -130 dBm, -148 dBm DANL with optional preamplifier

 

PXI SWITCH SPDT MODULE 26-CHANNELS 2A AGILENT M9130A

• General purpose switching to control external devices or
• switch in loads or power supplies
• 26-channel SPDT switch
• 2A switch/carry current
• 60W max power
• Durable, armature relays

 

DIGITAL OSCILLOSCOPE 4 X 100 MHZ AGILENT DSOX2014A

• 100 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

USB MODULAR DIGITAL I/O 32-CH. INPUT+32-CH. OUTPUT AGILENT U2651A

• Hi-Speed USB 2.0 (480 Mbps)
• 32 Input opto-isolated lines
• 32 Output opto-isolated lines
• Functions as standalone or modular unit
• Up to 1250 Vrms isolation protection

 

AGILENT N9344C HSA HANDHELD SPECTRUM ANALYZER 9 KHZ/ 1MHZ..20 GHZ

• 1 MHz to 20 GHz Frequency range(tunable to 9 kHz)
• 10 Hz to 3 MHz RBW
• 1 Hz to 3 MHz VBW

 

AGILENT 16806A PORTABLE LOGIC ANALYZER 204 CHANNELS

• 204-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

FET MULTIPLEXER MODULE 40/80 OPTICALLY ISOLATED CHANNELS AGILENT 34925A

• 40 2-wire channels or 80 1-wire channels
• Mixed 2- or 4-wire configurations
• High-speed optically isolated FET switches, with relay counter

 

DATA ACQUISITION SOFTWARE AGILENT 34832 BENCHLINK DATA LOGGER PRO

• Quick test setup and execution
• Create multiple scan lists
• Execute different events based on predefined limits
• Use advanced math formulas
• Collect, monitor and manage data


AGILENT DSO6104L MODULAR OSCILLOSCOPE 4 X 1 GHZ

• 1 GHz bandwidth
• 4 scope channels (upgradeable to MSO with 16 digital channels)
• 4 GSa/s sample rate, 8 Mpts stand memory
• LXI class C compliant

 

USB MODULAR DATA ACQUISITION UNIT 64-CHANNELS 250KSA/S AGILENT U2355A

• High-speed USB 2.0
• 16-bit resolution
• 64 SE/32 DI multiplex analog input channels
• Up to 250 kSa/s sampling rate
• 2 12-bit analog output channels,
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels