Agilent N9000A CXA Signal Spectrum Analyzer 9 kHz..3 GHz or 7.5 GHz

Code: Agilent N9000A CXA


 

Datasheet PDF, 0.58 Mb

Description

  • 9 kHz to 3.0 or 7.5 GHz Frequency range
  • 10 MHz (standard), 25 MHz (optional) analysis bandwidth
  • Basic EMI precompliance measurement capability available
  • Standards-based PowerSuite: channel power, OBW, ACP, CCDF, SEM
  • ±0.5 dB absolute amplitude accuracy
  • +17 dBm third order intercept (TOI)
  • -163 dBm displayed average noise level (DANL)
  • -66 dB W-CDMA ACLR dynamic range (with noise correction on)
  • Advanced analysis of up to 70 signal formats, software runs inside CXA
  • LXI class C, SCPI and IVI-COM. USB 2.0, 100Base-T LAN, GPIB
  • Programming language compatibility with ESA and other X-Series
  • Common X-Series user interface / Open Windows® XP operating system
  • Internal preamplifier options up to 7.5 GHz
  • Optional built-in tracking generator 3 or 6 GHz
 

Recommended options

  • Option 503    9 kHz to 3.0 GHz
  • Option 507    9 kHz to 7.5 GHz
 

More products KEYSIGHT

AGILENT 34410A DIGITAL PRECISION MULTIMETER 6.5 DIGIT

• 6 ½ digit resolution
• Basic accuracy: .0030 % DC,0.06% AC
• 14 measurement functions including capacitance & temperature
• Data Logger with 50,000 reading non-volatile memory

 

AGILENT E4980A PRECISION LCR METER 20 HZ..2 MHZ

• 20 Hz to 2 MHz
• 4-digit resolution in any range
• 0.05% basic accuracy
• Measurement parameters: |Z|, |Y|, ?, R, X, G, B, L, C, D, Q, Rdc, Idc, Vdc
• High-speed measurements up to 5.6 ms

 

AGILENT 1602B HAND HELD DIGITAL OSCILLOSCOPE 2 X 20 MHZ

• 20 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 125KS Maximum recording length viewable on screen with zoom function

 

MULTIPLEXER MODULE QUAD 4-CHANNELS 50 OHM AGILENT 34941A

• Quad 4-channel multiplexers
• DC to 3 GHz, 50 Ohm
• High isolation, low VSWR
• 30V, 0.5A, 10W switching
• SMA connectors

 

AGILENT 81104A 81105A PULSE GENERATOR 80 MHZ

• 1 mHz to 80 MHz
• 1 or 2 Channels(order 2 x 81105A modules)
• 3 ns to 200 ms variable transition time
• Up to 10 Vpp into 50 O (20 Vpp into open circuit)

 

USB MODULAR DATA ACQUISITION UNIT 64-CHANNELS 250KSA/S AGILENT U2355A

• High-speed USB 2.0
• 16-bit resolution
• 64 SE/32 DI multiplex analog input channels
• Up to 250 kSa/s sampling rate
• 2 12-bit analog output channels,
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

DIGITAL OSCILLOSCOPE 4 X 350 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSOX3034A

• 350 MHz bandwidth
• 4 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


DIGITAL OSCILLOSCOPE 4 X 350 MHZ AGILENT DSO7034B

• 350 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

AGILENT DSO6014L MODULAR OSCILLOSCOPE 4 X 100 MHZ

• 100 MHz bandwidth
• 4 scope channels (upgradeable to MSO with 16 digital channels)
• 2 GSa/s sample rate, 2 Mpts stand memory
• LXI class C compliant

 

DIGITAL OSCILLOSCOPE 2 X 70 MHZ AGILENT DSOX2002A

• 70 MHz bandwidth
• 2 analog channels
• 1GSa/s per channel sample rate