Agilent 16802A Portable Logic Analyzer 68 channels

Code: Agilent 16802A


 

Datasheet PDF, 1.09 Mb

Description

  • 68-channel portable logic analyzer
  • 4 GHz (250 ps) timing zoom with 64 K memory
  • 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
  • 500 MHz transitional timing
  • up to 450 MHz State clock rates
  • up to 500 Mb/s Data rates
  • up to 32 M acquisition memory depth
  • 15-inch (38.1 cm) color display with touch screen available(option 103)
  • Comprehensive single-ended signal support, threshold is adjustable in -5 V to 5 V (10 mV increments)
  • Automated threshold/sample position setup for accurate measurements on high-speed buses
  • Simultaneous eye diagrams on all channels identify problem signals quickly
  • Selectable memory depths: 1 M, 4 M, 16 M, 32 M
 

Recommended options

16800A-0B3

Service Manual

16800A-103

Front Panel with 15 inch display and touchscreen

16800A-109

External removable hard drive for 16800 series logic analyzers

16802A-001

Standard 1 M acquisition memory depth

16802A-004

Increase acquisition memory depth to 4M

16802A-016

Increase acquisition memory depth to 16M

16802A-032

Increase acquisition memory depth to 32M

16802A-500

Increase maximum state speed to 500 Mb/s

16802A-A6J

ANSI Z540 Compliant Calibration

E5346A

Probe, 34 channel single-ended Mictor connector, connects to 40-pin LA cable

E5383A

Probe, 17-channel single-ended flying leads, connects to 40-pin LA cable

E5385A

Probe, 34 channel single-ended Samtec connector, connects to 40-pin LA cable

E5394A

Probe, 34 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5394A-001

Retention Module

E5396A

Probe, 17 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5396A-001

Retention Modules

E5403A

Kit of 5 retention modules for Pro Series Soft Touch Connectorless Probes

E5404A

Probe, 34 channel, soft touch pro, single-ended, connects to 40-pin LA cable

 

More products KEITHLEY

MULTIPLEXER MODULE 20 CHANNELS AGILENT 34901A

• 20 Channel Multiplexer
• Two- and four-wire scanning
• 300 V switching
• 60 ch/s scanning
• Built-in thermocouple reference junction

 

AGILENT E3631A E3632A E3633A E3634A DC PROGRAMMABLE POWER SUPPLIES 80-200W

• Single and triple output
• 80 W to 200 W output power
• Low noise and excellent regulation
• GPIB and RS-232 standard

 

AGILENT E4438C ESG VECTOR SIGNAL GENERATOR 250 KHZ..1 GHZ/ 2 GHZ/ 3 GHZ/ 4 GHZ/ 6 GHZ

• 250 kHz to 1 GHz, 2 GHz, 3 GHz, 4 GHz or 6 GHz
• 0.01 Hz resolution
• +17 dBm output power
• 64 MSa playback memory and 1 GSa storage
• 80 MHz dual mode internal baseband generator: arbitrary waveform and real-time I/Q

 

AGILENT 4263B LCR METER 100 HZ..100 KHZ

• 0.1% basic accuracy
• 100 Hz, 120 Hz, 1 kHz, 10 kHz, 20 kHz, 100 kHz test frequencies
• Measurement parameters: Z, Y, Theta, R, X, G, B, C, L, D, Q, Rdc, N, M

 

PXI MULTIPLEXER MODULE 99-CHANNELS 100V/1A AGILENT M9103A

• 99-channel, high-density 2-wire switch multiplexer
• 100Vrms
• 1A switch/carry current
• 60W max power
• Durable 60W armature switches

 

DIGITAL OSCILLOSCOPE 4 X 200 MHZ AGILENT DSOX2024A

• 200 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 250KSA/S SIMULTANEOUS AGILENT U2541A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 250 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

AGILENT 1604A HAND HELD DIGITAL OSCILLOSCOPE 2 X 40 MHZ

• 40 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 11KS Maximum recording length viewable on screen with zoom function

 

DIGITAL OSCILLOSCOPE 4 X 70 MHZ & LOGIC ANALYZER 8 CHANNELS AGILENT MSOX2004A

• 70 MHz bandwidth
• 4 analog channels plus 8 digital channels
• 1GSa/s per channel sample rate

 

AGILENT 6671A 6672A 6673A 6674A 6675A DC PROGRAMMABLE POWER SUPPLIES 2000W

• Fast, low-noise Single outputs
• Linear output regulation
• Overvoltage & overcurrent protection
• Measured V & I readback over GPIB