Maximum protection in Tempest and EMPP applications
-
Highest performing commercially available power line filter
-
Over 100dB insertion loss from 10 kHz to 10 GHz
-
Fully accessible end chambers
-
RoHS compliant and CE marked for compliance with the low voltage directive
Applications
-
Low power dissipation
-
Compact Rugged Construction
-
100dB insertion loss from 40kHz
-
Suitable for 400Hz supplies
-
Current Range 16 to 200 Amperes
APPLICATIONS
-
In high performance screened rooms and anechoic chambers the N500X series provides protection of both incoming and outgoing supplies in line with the shield performance.
-
In TEMPEST applications, the N500X filters provide an extremely high degree of protection required to obtain maximum security.
-
N500X filters are ideal for EMC applications such as computer suites.
-
N500X filters can be used for general purpose high performance filtering.
Electrical Specifications
PART # |
Current Max (Amps) |
Voltage Max (Volts) |
Frequency (Hz) |
Number of Lines |
Volt Drop on Full Load in a 250V 50/60Hz System per Line (Max) |
Full Load Dissipation |
5000 |
16 |
250 |
DC/50/60/400 |
2 |
1.3 |
20 |
5001 |
16 |
440/250 |
DC/50/60/400 |
4 |
0.65 |
20 |
5002 |
32 |
250 |
DC/50/60/400 |
2 |
0.3 |
20 |
5003 |
32 |
440/250 |
DC/50/60/400 |
4 |
0.15 |
20 |
5004 |
63 |
250 |
DC/50/60/400 |
2 |
0.4 |
48 |
5005 |
63 |
440/250 |
DC/50/60/400 |
4 |
0.2 |
48 |
5006 |
100 |
250 |
DC/50/60/400 |
2 |
0.3 |
60 |
5007 |
100 |
440/250 |
DC/50/60/400 |
4 |
0.15 |
60 |
5008 |
200 |
250 |
DC/50/60/400 |
2 |
0.2 |
80 |
5009 |
200 |
440/250 |
DC/50/60/400 |
4 |
0.1 |
80 |
-
High performance screen rooms, providing attenuation of both the incoming and outgoing mains supply lines to match the shield performance
-
Tempest applications, where the very highest degree of protection is required to obtain maximum security
-
EMP protection systems
Electrical Specifications
Part # |
Current Max |
Frequency |
Max Voltage |
# of Lines |
Voltage Drop On Full Load in 250V 50/50Hz System/Line |
DC Resistance Per Line |
N2550 |
6 A |
50/60 Hz |
250 V |
2 |
1 V |
50 Ω |
N2551 |
6 A |
50/60 Hz |
440/250 V |
4 |
1 V |
50 Ω |
N2552 |
16 A |
50/60 Hz |
250 V |
2 |
1 V |
12 Ω |
N2553 |
16 A |
50/60 Hz |
440/250 V |
4 |
1 V |
12 Ω |
N2554 |
32 A |
50/60 Hz |
250 V |
2 |
0.6 V |
24 Ω |
N2555 |
32 A |
50/60 Hz |
440/250 V |
4 |
0.6 V |
24 Ω |
N2556 |
63 A |
50/60 Hz |
250 V |
2 |
1.5 V |
15 Ω |
N2557 |
63 A |
50/60 Hz |
440/250 V |
4 |
1.5 V |
15 Ω |
N2558 |
100 A |
50/60 Hz |
250 V |
2 |
0.9 V |
5 Ω |
N2559 |
100 A |
50/60 Hz |
440/250 V |
4 |
0.9 V |
5 Ω |