Brand: HART SCIENTIFIC

Precision Reference 2-channel Thermometer Hart Scientific 1524

Code: Hart Scientific 1524


 

Datasheet PDF, 0.25 Mb

Description

  • Two channels
  • High accuracy
  • PRTs: up to ± 0.011 °C
  • Thermocouples: up to ± 0.24 °C
  • Precision thermistors: ± 0.002 °C
  • memory for logging 15,000 measurements
  • real-time clock for time and date stamps
 

Recommended options

1524

Reference Thermometer, Handheld, 2 Channel, Data Logger

1524-P1

1524 Bundled, with 5616 PRT, Universal TC INFO-CON Connector, TPAK, and Case

1524-P2

1524 Bundled with 5628 PRT, Universal TC INFO-CON Connector, TPAK, and Case

1524-P3

1524 Bundled with 5627A PRT, Universal TC INFO-CON Connector, TPAK, and Case

 

More products HART SCIENTIFIC

INFRARED TEMPERATURE CALIBRATOR 50°C/ 100°C/ 150°C HART SCIENTIFIC 9135

• Fast and easy IR calibrations
• Three temperatures available: 50 °C, 100 °C, and 150 °C
• NIST-traceable calibration included

 

TEMPERATURE CALIBRATION OIL MICRO-BATH -5°C..125°C HART SCIENTIFIC 7102

• -5 °C to 125 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.015 °C

 

FLUKE HART SCIENTIFIC 1594A 1595A TEMPERATURE, THERMOMETER, THERMISTOR CALIBRATOR

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

THERMOCOUPLE FURNACE CALIBRATOR 300°C..1100°C HART SCIENTIFIC 9112B

• 300 °C to 1100 °C temperature range
• Combined stability and uniformity better than ±0.4°C
• RS-232 serial interface standard
• High capacity for simultaneous comparison calibrations

 

FIELD DRY WELL TEMPERATURE CALIBRATOR -25°C..140°C HART SCIENTIFIC 9103

• -25 °C to 140 °C range
• Lightweight and very portable
• Accuracy to ±0.25 °C
• ± 0.02 °C stability

 

METROLOGY THERMOMETER CALIBRATION WELL -30°C..155°C HART SCIENTIFIC 9171

• -30 °C to 155 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

METROLOGY THERMOMETER CALIBRATION WELL 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

METROLOGY THERMOMETER CALIBRATION WELL -45°C..140°C HART SCIENTIFIC 9170

• -45 °C to 140 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL -25°C..150°C HART SCIENTIFIC 9142

• -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.01 °C