Brand: HART SCIENTIFIC

Logging Thermo-Hygrometer Hart Scientific DewK 1620A

Code: Hart Scientific DewK 1620A


 

Datasheet PDF, 0.27 Mb

Description

  • Superior accuracy 
  • NEW! Network enabled 
  • Powerful logging and analysis tools 
  • Two interchangeable calibrated sensors 
  • Huge memory 
 

Recommended options

1621A-H 

The "DewK" Thermo-Hygrometer, High-Accuracy Value Kit (includes two high-accuracy sensors, wall mount bracket, RS-232 cable, 7.6 m [25 ft] sensor extension cable, sensor wall mount bracket, sensor case, and 9936A LogWare III single-PC license) 

1622A-H

 The "DewK" Thermo-Hygrometer, USB Wireless High-Accuracy Value Kit (includes 1621A-H Value Kit, 2633-RF, and 2633-USB)

1620A-H 

The "DewK" Thermo-Hygrometer, High-Accuracy (includes one high-accuracy sensor, wall mount bracket, and RS-232 cable) 

1621A-S 

The "DewK" Thermo-Hygrometer, Standard-Accuracy Value Kit (includes two standard-accuracy sensors, wall mount bracket, RS-232 cable, 7.6 m [25 ft] sensor extension cable, sensor wall mount bracket, sensor case, and 9936A LogWare III single-PC license) 

1622A-S

The "DewK" Thermo-Hygrometer, USB Wireless Standard-Accuracy Value Kit (includes 1621A-S Value Kit, 2633-RF, and 2633-USB)

1620A-S 

The "DewK" Thermo-Hygrometer, Standard-Accuracy (includes one standard-accuracy sensor, wall mount bracket, and RS-232 cable) 

Sensors 

2626-H 

Spare Sensor, high-accuracy 

2627-H 

Spare Sensor Kit (includes high-accuracy sensor, sensor case, sensor wall mount bracket, and 7.6 m [25 ft] extension cable) 

2626-S 

Spare Sensor, standard-accuracy 

2627-S 

Spare Sensor Kit, (includes standard-accuracy sensor, sensor case, sensor wall mount bracket, and 7.6 m [25 ft] extension cable) 

 

More products FLUKE

PRECISION REFERENCE 2-CHANNEL THERMOMETER HART SCIENTIFIC 1524

• Two channels
• High accuracy
• PRTs: up to ± 0.011 °C
• Thermocouples: up to ± 0.24 °C
• Precision thermistors: ± 0.002 °C
• memory for logging 15,000 measurements

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL 35°C..375°C HART SCIENTIFIC 9100S

• 35°C to 375°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.07°C at 0°C

 

TEMPERATURE CALIBRATION OIL MICRO-BATH 35°C..200°C HART SCIENTIFIC 6102

• 35 °C to 200 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.02 °C

 

METROLOGY THERMOMETER CALIBRATION WELL -30°C..155°C HART SCIENTIFIC 9171

• -30 °C to 155 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

SURFACE SENSOR CALIBRATOR 35°C..400°C HART SCIENTIFIC 3125

• Calibrates surface sensors up to 400°C
• Uses Hart 2200 Controller for excellent accuracy and stability
• NIST-traceable calibration included

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL =10°C..122°C HART SCIENTIFIC 9102S

• -10°C to 122°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.05°C at 0°C

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL 33°C..350°C HART SCIENTIFIC 9143

• 33 °C to 350 °C (91 °F to 662 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.02 °C

 

FLUKE HART SCIENTIFIC 1594A 1595A TEMPERATURE, THERMOMETER, THERMISTOR CALIBRATOR

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

TEMPERATURE CALIBRATION OIL MICRO-BATH -5°C..125°C HART SCIENTIFIC 7102

• -5 °C to 125 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.015 °C

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability