Fluke 8845A Digital Bench Multimeter 6.5 digit

Code: Fluke 8845A


 

Datasheet PDF, 0.55 Mb

Description

  • 6.5 digit resolution
  • Basic Vdc accuracy 0.0035 %
  • Dual display
  • 100 µA to 10 A current range, with up to 100 pA resolution
  • Wide ohms range from 10 O to 1 GO with up to 10 µO resolution
  • 2 x 4 ohms 4-wire measurement technique
  • Both models measure frequency and period
  • Fluke 45 and Agilent 34401A emulation
  • Graphical display
  • Trendplot™ paperless recorder mode, statistics, histogram
  • CAT I 1000 V, CAT II 600 V
 

Standard accessories

  • TL71 Test Lead Set, Premium DMM
  • LCI Line Cord
  • USB to RS232 Cable Adapter
  • Statement of Calibration Practices
  • WEEE Information Sheet
  • Warranty Information
  • Programmer, Users and Service Manuals (CD-ROM)
  • FlukeView Forms - Basic for 8845/8846
 

More products FLUKE

FLUKE 124B 124B/S INDUSTRIAL SCOPEMETER HAND-HELD OSCILLOSCOPE 2X40MHZ

• 2-channel 40MHz
• Dual-input digital oscilloscope and multimeter
• 40 MHz or 20 MHz oscilloscope bandwidth
• Two 5,000-count true-rms digital multimeters
• Power measurements (W, VA, VAR, PF, DPF, Hz)
• Voltage, current and power harmonics
• Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*

 

THERMOCOUPLE TEMPERATURE CALIBRATOR FLUKE 714

• -200 to 1800șC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

MOTOR PHASE ROTATION INDICATOR FLUKE 9062

• 3 phase indication
• Indication of phase rotation
• Indication of motor rotation direction
• Contact free determination of the rotation direction of running motors

 

FLUKE CNX 3000 WIRELESS DIGITAL MULTIMETER

• AC and DC voltage measurements to 1000V
• AC and DC current with 0.01 mA resolution
• Continuity, resistance, diode test, capacitance and frequency measurements
• MIN/MAX Recording
• CAT III 1000 V, Cat IV 600V; IP54

 

FLUKE 700PTP-1 PNEUMATIC TEST PUMP FOR PRESSURE CALIBRATION

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke

 

WIRELESS AC CURRENT MEASUREMENT KIT FLK-CNX I3000 IFLEX KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• Memory recording up to 65,000 readings
• CAT III 1000, CAT IV 600 V; IP42


FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 323

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection

 

REMOTE AC CURRENT MEASUREMENT KIT WITH CURRENT CLAMP FLUKE FLK-CNX A3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 400 A
• Memory recording up to 65,000 readings
• CAT III 600 V; IP42