Fluke 116 Handheld Digital Multimeter HVAC 3.5 digit

Code: Fluke 116


 

Datasheet PDF, 0.13 Mb

Description

  • 3.5 digit
  • 6000 count
  • 0.5% accuracy
  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated
 

Standard accessories

  • Test leads with 4 mm lantern tips and
  • protective cap
  • holster
  • installed 9V battery
  • users manual
 

More products FLUKE

MULTIFUNCTIONAL TESTER FOR TEMPERATURE, HUMIDITY, VELOCITY, CO, CO2 FLUKE 075 AIRMETER

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 353

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• Accurately measure frequency up to 1 kHz

 

FLUKE MEMOBOX 1744 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

FLUKE 700HTP-2 HYDRAULIC TEST PUMP FOR PRESSURE CALIBRATION

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

UNIVERSAL CALIBRATOR FLUKE 9100

• Calibrates over 15 different categories of general-purpose test equipment
• Options for power meter, insulation/continuity tester and oscilloscope calibration
• Semi-automated and fully automated procedure modes
• Fully supported by MET/CAL Plus software
• Intuitive front panel operation for ease of use

 

FLUKE TIS55 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

CARBON MONOXIDE TESTER FLUKE CO-220

• Rugged case and electronics.
• Large LCD displays CO levels from 0 to 1000 ppm.
• Bright back-light allows easy screen viewing under dim lighting conditions.
• Beeper triggers with increasing frequency as CO levels rise.
• MAX Hold function stores and displays the maximum CO level.
• Automatic sensor zeroing and self-test sequence upon start-up.

 

FLUKE 233 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.25% accuracy
• Remote Display
• Measure up to 1000 V ac and dc
• Measure up to 10 A (20 A for 30 seconds)
• 10,000 µF capacitance range
• Frequency to 50 kHz
• True-rms ac voltage and current for accurate measurements on non-linear signals

 

DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II

• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Measures J, K, T, and E-types of thermocouples
• Readout in ºC, ºF, or Kelvin (K)
• Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)