Fluke 6306 Automatic RCL Meter 50 Hz..1 MHz

Code: Fluke 6306


 

Datasheet PDF, 0.08 Mb

Description

  • 50, 60, 100, 120 Hz  200 Hz to 100 kHz (100 Hz steps)
  • 100 kHz to 1 MHz (1 kHz steps) test frequencies
  • 0.1 % basic accuracy
  • Easy to use, at-a-glance display
  • RS-232 and IEEE-488 interfaces
  • AC test levels from 50 mVrms to 2 Vrms
  • Internal or external bias
  • DC test measurement (optional)
  • 9 front panel set-ups
  • Actual component test voltage/current readback
  • Automatic zero trimming
  • Front-panel test posts for immediate 4-wire measurements
  • Contact check and deviation mode
 

More products FLUKE

FLUKE 190-202 190-202/S HANDHELD DIGITAL OSCILLOSCOPE 2X200 MHZ

• 2-channels isolated 200MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 743B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging

 

WIRELESS AC VOLTAGE MODULE FLUKE CNX V3000

• True-RMS AC voltage measurements to 1000V
• ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V; IP42


FLUKE 700HTP-2 HYDRAULIC TEST PUMP FOR PRESSURE CALIBRATION

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


VOLTAGE DETECTOR FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display

 

INDUSTRIAL MEASUREMENT SYSTEM FLUKE CNX 3000 HVAC

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• Temperature measurements from -200 °C to 1372 °C
• True-RMA AC current measurements to 400 A


FLUKE VR1710 SINGLE PHASE VOLTAGE QUALITY RECORDER

• 70 V to 300 V Operating Voltage
• Fast and easy recording of voltage trends, dropouts, and power quality
• Continuous recording of all values with no gaps
• Flicker recording to EN 61000-4-15, individual harmonic and THD values
• Min, Max, and Average RMS values