Fluke 115 Handheld Digital Multimeter 3.5 digit

Code: Fluke 115


 

Datasheet PDF, 0.13 Mb

Description

  • 3.5 digit
  • 6000 count
  • 0.5% accuracy
  • AC/DC Current
  • Capacitance and Frequency
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated Safety conformance: All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE
 

Standard accessories

  • Test leads with 4 mm lantern tips and
  • protective cap
  • holster
  • installed 9V battery
  • users manual
 

More products FLUKE

VOLTAGE DETECTOR FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 325

• 400 A ac and dc current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement
• Frequency measurement

 

VOLTAGE DETECTOR FLUKE 2AC VOLTALERT

• Voltage detection from 200 to 1000 V AC
• Category IV - 1000 V overvoltage rated product

 

FLUKE 721 PRESSURE CALIBRATOR

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

FLUKE 700HTP-2 HYDRAULIC TEST PUMP FOR PRESSURE CALIBRATION

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

AC VOLTAGE DATA ACQUISITION RECORDING KIT FLUKE FLK-CNX V3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC voltage measurements to 1000V
• Memory recording up to 65,000 readings
• CAT III 1000 V; CAT IV 600 V; IP42


DIGITAL PYROMETER FLUKE 63

• Single point offset laser sighting
• Best accuracy in its class: + 1% of reading
• Holds temperature readings for 7 seconds
• Dual displays shows current and MAX measurements simultaneously
• Backlit display for poorly lit areas
• Wide temperature range from -30º to 500ºC (-20º to 932ºF)

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

FLUKE 700PTP-1 PNEUMATIC TEST PUMP FOR PRESSURE CALIBRATION

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke

 

FLUKE 345 POWER QUALITY CLAMP METER

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current