Extech PQ3350-3 3-Phase Power & Harmonics Analyzer

Code: Extech PQ3350-3


 

Datasheet PDF, 0.37 Mb

Description

Complete with 3000A 24" flexible current clamp probes

Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

 

Features:

  • Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings)
  • Flexible clamp probes can be used for wrapping around bus bars and wire bundles
  • Large backlighting LCD displays up to 35 parameters in one screen
  • Clamp-on True RMS power measurements with on-screen Harmonics display
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 3000) and VT ratio (1 to 600)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics
  • Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
 

More products EXTECH

EXTECH CO15: CARBON MONOXIDE (CO) METER

• Dual LCD simultaneously displays Carbon Monoxide (CO) level and maximum CO reading taken from when the meter was powered on
• Long life electrochemical sensor
• Adjustable CO warning level at 25, 30, 35, 45, 50, 70, 100 and 200ppm (alarm is preset to 25ppm)
• Audible alarm when CO level reaches the warning set point level
• Choose from 3 calibration points: 0 (preset), 100, and 500ppm

 

EXTECH 382280: PRECISION WITH PROGRAMMABLE 200 WATT OUTPUT DC POWER SUPPLY

• High resolution (1mV and 1mA) user programmable output
• Selectable constant Voltage or Current modes
• 0 to 60 second programmable overload delay timer
• Storage/Recall memory

 

EXTECH MG500 DIGITAL HIGH VOLTAGE INSULATION TESTER 10KV

• High test voltages up to 10kV with Insulation Resistance to 500GOhm
• Polarization Index (PI) measurement
• Dielectric Absorption Ratio (DAR) measurement
• EnerSave™ limits test duration to 10 seconds to save energy
• Complete with built-in heavy duty carrying case with cover, test leads, alligator clips, and 8 x C batteries

 

EXTECH LRK15 LIGHTING RETROFIT KIT WITH POWER CLAMP METER

• Designed for professionals who routinely audit existing and replacement lighting systems for energy efficiency and lighting performance
• Kit includes:
• LT300 - Light meter with digital and analog display of light in Foot-candles or Lux
• DT200 - Compact laser distance meter with area/volume calculation functions
• 380940 - 400A True RMS AC/DC power clamp meter
• Supplied in a soft carrying case that provides protection and organization for the meters whenever they are needed

 

EXTECH ET10: GFCI RECEPTACLE TESTER

• Works with GFCI circuits
• Tests for faulty wiring in 3-wire receptacles: Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse
• Lights indicate circuit condition
• Standard North American 3-prong plug

 

EXTECH MO230 POCKET MOISTURE METER

• Displays moisture in wood and other building materials plus Air Temperature and Relative Humidity
• Digital LCD readout with analog bargraph and numerical displays
• Simultaneous digital readout of moisture content plus ambient temperature or humidity with analog bargraph display of moisture, Max moisture values, and programmable wet/dry indication
• Use on wood, paper, wall board, sheet rock, cardboard, plaster, concrete, and mortar

 

EXTECH LT10 POCKET SERIES LIGHT METER

• Measures light intensity up to 4000Fc/40000Lux with measuring rate of 1.5 times/second
• Pocket-sized housing with easy one-button operation
• Large, backlit LCD display
• Double-molded side grip
• Tripod mount (tripod not included)
• Complete with 9V battery

 

EXTECH 401025 FOOT CANDLE/LUX LIGHT METER

• Accurately displays light level in terms of Fc or Lux over three ranges
• Select fast (1 second) or slow (2 seconds) response time
• Analog output of 1mV per count for capturing readings to a recorder

 

INSPECTION VIDEO CAMERA BOREOSCOPE EXTECH BR150

• 9mm diameter camera head
• 39" (1m) flexible gooseneck cable retains configured shape
• High resolution
• mini waterproof (IP67) camera head
• four built-in bright LED lamps and dimmer function
• Display detaches for easy storage

 

EXTECH EX470 12 FUNCTION TRUE RMS PROFESSIONAL MULTIMETER + INFRARED THERMOMETER

• True RMS DMM with 12 functions and 0.3% basic accuracy
• AC/DC Voltage & Current, Resistance, Capacitance, Frequency, TypeK & IR Temperature, Diode/Continuity, Duty Cycle
• Built-in non-contact InfraRed Thermometer with 8:1 distance to target ratio with 0.95 fixed emissivity
• Input fuse protection and mis-connection warning
• 20A max Current