Double-Ridged Waveguide Horn Antenna for EMC Measurements 400 MHz..6 GHz ETS-Lindgren 3119

Code: ETS-Lindgren 3119


 

Datasheet PDF, 0.39 Mb

Description

  • Frequency Minimum     400 MHz
  • Frequency Maximum    6 GHz
  • VSWR Ratio (AVG)    3.5:1 max
  • <2:1 above 500 MHz
  • Maximum Continuous Power    1500 W @ 400 MHz, 800 W @ 6 GHz
  • Peak Power     2500 W
  • Impedance (Nominal)   50 ?
  • Connectors       Type N
  • Ultra Broadband: 400 MHz - 6 GHz
  • 1500 W Power Input Capacity
  • Optimized High Frequency Gain
  • Low VSWR
  • Flexible Mounting System
 

More products ETS-LINDGREN

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

PASSIVEELECTRIC FIELD MONOPOLE TRANSMITTING ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMI/ EMC TEST CURRENTS 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

RFI/ EMI FEED-THROUGH CAPACITORS FOR AC/ DC CIRCUIT SUPPLY ETS-LINDGREN L265X

• All brass construction
• Excellent dv/dt characteristics
• These filters have NATO stock number codification
• High voltage proof withstand
• Design to meet Class Y specification

 

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity