Description
E8000A handheld spectrum analyzer is an ideal testing instrument for engineer working at the wireless base station for 2G/3G/4G, WiFi and broadcast installation and maintenance.
E8000A covers frequency range: 100 kHz ~ 3000 MHz and has tracking generator option.
Large Dynamic Range Spectrum Analysis
E8000 series covers wide frequency range: 100 kHz ~3000 MHz and provide +15dBm IP3 and lower noise.
Interference Signals Analysis
E8000A provides features such as signal strength indication, spectrogram and fluorogram to find out interference signals.
E8000A supports FM/AM demodulation and then distinguishes noise through speaker or earphone to locate interference signals.
Fast Sweep Speed
E8000A provides 1 ms minimum sweep time to detect any complex interference signals.
RF Signals Analysis Function
E8000A provides one-button measurement for channel power, OBW and adjacent channel power.
GPS Receiver Option
GPS receiver option provides location (longitude, latitude, altitude) and Universal Time (UT) information. For the E8000A series, all measurement results can be saved with location and time information.
|
Frequency | |
|
Frequency Range |
100 kHz ~ 3000 MHz |
|
Frequency Reference | |
|
Aging |
± 1 ppm per year |
|
Stability |
± 1 ppm |
|
Temperature Stability |
± 2 ppm (0 to +50ºC) |
|
Frequency Resolution |
10 Hz |
|
Marker Count Accuracy (S/N 25 dB, RBW/span 0.01) | |
|
Accuracy |
±2 ppm, ±1 count |
|
Counter Resolution |
1 Hz |
|
Frequency Span | |
|
Range |
0 Hz (Zero Span), 1 kHz to 3000 MHz |
|
Sweep and Trigger | |
|
Range |
1 mSec to 250 sec (Span > 1 kHz) 20 µSec to 500 sec (Span = 0 Hz) |
|
Accuracy |
< ± 0.2% |
|
Trigger Type |
Free run, Single, Video, TV |
|
Resolution Bandwidth | |
|
Range |
10 Hz to 3 MHz in 1-3-10 sequence |
|
Bandwidth Accuracy |
< ± 10% |
|
Selectivity (60 dB/3 dB Bandwidth Ratio) |
< 5:1 |
|
Video Bandwidth | |
|
Range |
10 Hz to 1 MHz in 1-3-10 sequence |
|
Stability | |
|
Phase Noise |
< -105 dBc/Hz @ 100 kHz offset from CW signal < -95 dBc/Hz @ 10 kHz offset from CW signal < -85 dBc/Hz @ 1 kHz offset from CW signal |
|
Amplitude | |
|
Measurement Range |
Displayed average noise level to furthest safe input level |
|
Input Attenuator | |
|
Range |
0 dB ~ 50 dB |
|
Step |
5 dB |
|
Internal Preamplifier | |
|
Frequency Range |
1 MHz to 3000 MHz |
|
Gain |
15 dB |
|
Max. Safe Input |
+30 dBm (peak power/input attenuation >15 dB), 100 VDC |
|
Displayed Average Noise Level (Input Terminated, 0 dB Attenuator, RBW=100 Hz, VBW=3 Hz, Sample Detector) | |
|
Pre-amplifier OFF (Typical) |
< -130 dBm 1 MHz ~ 1 GHz < -126 dBm 1 GHz ~ 3 GHz |
|
Pre-amplifier ON (Typical) |
< -145 dBm 1 MHz ~ 1 GHz < -141 dBm 1 GHz ~ 3 GHz |
|
Spurious Responses | |
|
Second Harmonic |
< -70 dBc for -20 dBm signal at input mixer |
|
TOI |
>+15 dBm (two -20 dBm signals at input mixer with =1 MHz separation and att=0) |
|
Residual Responses (Input Terminated and 0 dB Attenuator) |
< -85 dBm 1 MHz to 3000 MHz |
|
Display Range | |
|
Log Scale |
0.1 to 1 dB/div in 0.1 dB step 1 to 40 dB/div in 1 dB step |
|
Linear Scale |
10 divisions |
|
Scale Units |
dBm, dBmV, dBµV, mV |
|
Marker Readout Resolution |
0.03 dB for log scale 0.03% of ref level for linear scale |
|
Traces |
3 traces |
|
Trace Detector |
Sample, Posi-peak, Neg-peak, Normal, Average |
|
Marker Functions |
Peak, Next peak, Marker to center, Marker to ref, etc. |
|
Marker Display |
Normal, Delta, Fix marker & Frequency counter |
|
Reference Level |
-130 dBm to +30 dBm |
|
Level Accuracy |
< ± 1 dB @ +25ºC (Typical) |
|
Input/Output | |
|
RF Input | |
|
Input |
N connector |
|
Input Impedance |
50 O |
|
USB Port |
USB 2.0 port and USB 1.1 port |
|
LAN Port |
10 M / 100 M RJ45 |
|
TG Out | |
|
Output |
N connector |
|
Frequency Range |
10 MHz to 3000 MHz |
|
Phase Noise |
< -70 dBc/Hz @ 10 kHz |
|
Level Range |
-30 dBm to 0 dBm |
|
Level Resolution |
1 dB |
|
Level Accuracy |
± 2 dB |
|
Harmonic Distortion |
< -20 dBc |
|
Non-Harmonic Distortion |
< -30 dBc |
|
Output Impedance |
50 O |
|
Power Specifications | |
|
Battery Type |
11.1V @ 5.2Ah Lithium-lon |
|
Charge Time |
< 5 Hours |
|
Operating Time |
> 3.5 Hours |
|
AC Adapter |
19 V DC @ 3.42 A |
|
Other Specifications | |
|
Operating Temperature |
-10 ºC to +55 ºC |
|
Storage Temperature |
-30 ºC to +80 ºC |
|
Dimension (W x H x D) |
258 mm x 173 mm x 74 mm |
|
Weight (With Battery) |
<2.2 kg |
|
Display Type |
6.5 inch TFT color LCD |
|
Display Resolution |
640 x 480 pixels |
|
Language |
Chinese, English |
More products DEVISER
|
DEVISER DS2460Q QAM ANALYSIS METER
• Client-based Toolbox management software for quick unit configuration
|
|
TV TESTER FOR ANALOG, DIGITAL CABLE DVBC AND HFC INTALLATION NETWORKS DEVISER DS6300C
• mainly applied for the installation of data service of HFC Network |
|
DEVISER AE600 CWDM CHANNEL ANALYZER
• Analyze 18 wavelengths (ranging from 1271 ~ 1611nm) simultaneously
|
|
DEVISER DS2500Q DIGITAL TV QAM ANALYZER
• High Speed Spectrum Analysis: 4~1000MHz
|
|
DEVISER AE3100 SERIES HANDHELD OTDR
• Broad dynamic range coverage (28 - 39 dB)
|
|
PON OPTICAL FIBER POWER METER DEVISER EP300
• Simultaneous measurement of all EPON signal(1310 nm, 1490 nm and 1550 nm) on the fiber |
|
DEVISER AE210 SERIES OPTICAL POWER METER
• Over 100 hours' working time with 2x AA rechargeable batteries
|
|
DEVISER C1200 DVB-C METER
• Analog TV Analysis: Level, Tilt, C/N, Scan and Trunk Voltage
|
|
OPTIC LIGHT SOURCE DEVISER LS
• light source qualified in optical network, CATV and FTTX maintenance |
|
DEVISER E7000B CABLE & ANTENNA ANALYZER
• Reduce test time with dual measurement display to make two measurements simultaneously
|