Digital Oscilloscope 4 x 200 MHz & Logic Analyzer 16 channels Agilent MSOX3024A

Code: Agilent Infiniivision MSOX3024A


 

Datasheet , 0.33 Mb

Description

  • 200 MHz bandwidth
  • 4 analog channels plus 16 digital channels
  • 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode
  • Largest screen in its class: 8.5-inch WVGA display
  • Fastest update rate of 1,000,000 waveforms per second
  • Deepest memory: 4 Mpts
  • Best-in-class oscilloscope
  • Integrated logic timing analyzer (MSO)
  • Only built-in 20-MHz function generator: WaveGen
  • Only hardware-based protocol analyzer
  • Upgradability: add bandwidth, digital channels, or WaveGen after purchase
  • Optional serial protocol analysis applications including: I²C, SPI, RS232, UART, CAN, LIN, and I²S
  • Segmented memory
  • Mask Testing
 

Standard accessories

  • 4 x N2863B Passive probe 300 MHz 10:1 attenuation
  • N6450-60001 16 digital channel MSO probe
  • Calibration Certificate
  • Power Cord
  • Software
  • Manual
 

Recommended options

Options

 

DSOX3BW34

Bandwidth upgrade from 200 MHz to 350 MHz

DSOX3WAVEGEN

WaveGen (built-in function generator)

DSOX3MSO

MSO Upgrade: upgrades your 3000 X-Series scope to 16 digital timing channels

DSOX3MEMUP

Memory Upgrade: 4 Mpts half-channel

DSOXEDK

Educator"™s kit

DSOX3MASK

Mask testing

DSOX3SGM

Segmented memory

DSOX3EMBD

Embedded serial triggering and analysis (I2C, SPI)

DSOX3COMP

Computer serial triggering and analysis (RS232/422/485/UART)

DSOX3AUTO

Automotive serial triggering and analysis (CAN, LIN)

DSOX3AUDIO

Audio serial triggering and analysis (I2S)

U1881A

Power measurement and analysis

B4610A

PC offline viewing

 

Recommended Probes

 

N2889A

350 MHz passive probe 10:1/1:1 switchable attenuation

10076A

250 MHz 100:1, 4 kV high-voltage passive probe

N2771B

passive probe 50 MHz 1000:1 attenuation

N2795A

single-ended active probe 1 GHz ±8 V with AutoProbe interface

N2790A

differential active probe 100 MHz ±1.4 kV with AutoProbe interface

N2792A

differential active probe 200 MHz ±20V

N2793A

differential active probe 800 MHz ±15V

1146A

100 kHz, 100 A, AC/DC current probe

1147A

AC/DC current probe 50 MHz 15 A with AutoProbe interface

N2893A

AC/DC current probe 100 MHz 15 A with AutoProbe interface

 

Recommended Accessories

 

DSOXLAN

LAN/VGA connection module

DSOXGPIB

GPIB connection module

N6456A

Rack mount kit

N6457A

Soft carrying case and front panel cover

N6458A

Hard copy manual

 

 

More products Agilent 3000X 100-500MHz

MULTIFUNCTION MODULE I/O AGILENT 34907A

• 16 bits of digital input and output
• 100 kHz totalizer input
• Two +/-12V analog outputs

 

RF MULTIPLEXER MODULE 2 GHZ DUAL 1:4 75 OHM AGILENT 34906A

• Dual 4 Channel RF Multiplexer
• 2 GHz bandwidth, 75 Ohm
• Cascade together for up to 16:1 multiplexer
• BNC to SMB adapter cables included

 

DIGITAL OSCILLOSCOPE 4 X 500 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSO7054B

• 500 MHz bandwidth
• 4 GSa/s sample rate
• 4 analog plus 16 digital channels
• Standard 8 Mpts MegaZoom III deep memory

 

MULTIPLEXER MODULE 40 CHANNELS AGILENT 34908A

• 40 Channel Single-Ended Multiplexer
• Single-wire switching for common-low applications
• 60 ch/s scanning
• Built-in thermocouple reference junction

 

AGILENT E8663D PSG RF SIGNAL GENERATOR 100 KHZ..3.2 GHZ/ 9 GHZ

• 100 kHz to 3.2 GHz or 9 GHz
• 0.001 Hz resolution
• -135 to +24 dBm typical output power with Option 1EU
• AM, FM, ØM, and pulse (may be simultaneously enabled)

 

SWITCH MODULE 64 CHANNELS AGILENT 34939A

• 64 Form A channels up to 1A, 50W
• Latching armature relays, with relay cycle counter
• Temperature sensor for overheating conditions

 

USB THERMOCOUPLE INPUT MODULE 31-CHANNELS AGILENT U2802A

• Up to 31 thermocouple inputs
• Configurable for thermocouple or voltage input mode independently
• Voltage input range up to 10V
• Supports thermocouple type J, K, R, S, T, N, E and B

 

AGILENT 81104A 81105A PULSE GENERATOR 80 MHZ

• 1 mHz to 80 MHz
• 1 or 2 Channels(order 2 x 81105A modules)
• 3 ns to 200 ms variable transition time
• Up to 10 Vpp into 50 O (20 Vpp into open circuit)

 

USB MODULAR DATA ACQUISITION UNIT 64-CHANNELS 500KSA/S AGILENT U2356A

• High-speed USB 2.0
• 16-bit resolution
• 64 SE/32 DI multiplex analog input channels
• Up to 500 kSa/s sampling rate
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

DATA ACQUISITION MAINFRAME UNIT 8-SLOT AGILENT 34980A

• 8-Slot mainframe
• integrated 6.5 digit DMM
• 19 Plug-in modules - DC to 20 GHz switching
• Digital I/O
• D/A Converter
• Counter/Totalizer
• Standard LAN, USB, GPIB connectivity