Digital Oscilloscope 4 x 200 MHz & Logic Analyzer 16 channels Agilent MSOX3024A

Code: Agilent Infiniivision MSOX3024A


 

Datasheet , 0.33 Mb

Description

  • 200 MHz bandwidth
  • 4 analog channels plus 16 digital channels
  • 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode
  • Largest screen in its class: 8.5-inch WVGA display
  • Fastest update rate of 1,000,000 waveforms per second
  • Deepest memory: 4 Mpts
  • Best-in-class oscilloscope
  • Integrated logic timing analyzer (MSO)
  • Only built-in 20-MHz function generator: WaveGen
  • Only hardware-based protocol analyzer
  • Upgradability: add bandwidth, digital channels, or WaveGen after purchase
  • Optional serial protocol analysis applications including: I²C, SPI, RS232, UART, CAN, LIN, and I²S
  • Segmented memory
  • Mask Testing
 

Standard accessories

  • 4 x N2863B Passive probe 300 MHz 10:1 attenuation
  • N6450-60001 16 digital channel MSO probe
  • Calibration Certificate
  • Power Cord
  • Software
  • Manual
 

Recommended options

Options

 

DSOX3BW34

Bandwidth upgrade from 200 MHz to 350 MHz

DSOX3WAVEGEN

WaveGen (built-in function generator)

DSOX3MSO

MSO Upgrade: upgrades your 3000 X-Series scope to 16 digital timing channels

DSOX3MEMUP

Memory Upgrade: 4 Mpts half-channel

DSOXEDK

Educator"™s kit

DSOX3MASK

Mask testing

DSOX3SGM

Segmented memory

DSOX3EMBD

Embedded serial triggering and analysis (I2C, SPI)

DSOX3COMP

Computer serial triggering and analysis (RS232/422/485/UART)

DSOX3AUTO

Automotive serial triggering and analysis (CAN, LIN)

DSOX3AUDIO

Audio serial triggering and analysis (I2S)

U1881A

Power measurement and analysis

B4610A

PC offline viewing

 

Recommended Probes

 

N2889A

350 MHz passive probe 10:1/1:1 switchable attenuation

10076A

250 MHz 100:1, 4 kV high-voltage passive probe

N2771B

passive probe 50 MHz 1000:1 attenuation

N2795A

single-ended active probe 1 GHz ±8 V with AutoProbe interface

N2790A

differential active probe 100 MHz ±1.4 kV with AutoProbe interface

N2792A

differential active probe 200 MHz ±20V

N2793A

differential active probe 800 MHz ±15V

1146A

100 kHz, 100 A, AC/DC current probe

1147A

AC/DC current probe 50 MHz 15 A with AutoProbe interface

N2893A

AC/DC current probe 100 MHz 15 A with AutoProbe interface

 

Recommended Accessories

 

DSOXLAN

LAN/VGA connection module

DSOXGPIB

GPIB connection module

N6456A

Rack mount kit

N6457A

Soft carrying case and front panel cover

N6458A

Hard copy manual

 

 

More products Agilent 3000X 100-500MHz

AGILENT 4294A PRECISION IMPEDANCE ANALYZER 40 HZ..110 MHZ

• 40 Hz to 110 MHz
• +/-0.08% Basic impedance accuracy
• 3 milliohm to 500 Megohm

 

MULTIFUNCTION MODULE I/O AGILENT 34907A

• 16 bits of digital input and output
• 100 kHz totalizer input
• Two +/-12V analog outputs

 

DIGITAL OSCILLOSCOPE 2 X 100 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSOX3012A

• 100 MHz bandwidth
• 2 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


SWITCH/ATTENUATOR DRIVER MODULE AGILENT 34945A

• Control of most popular microwave switches and attenuators
• Expandable with 34945EXT Remote Module
• Distribution boards for ease of wiring
• Switch readback capabilities
• External power option for simultaneous switching

 

USB MODULAR DATA ACQUISITION UNIT 64-CHANNELS 500KSA/S AGILENT U2356A

• High-speed USB 2.0
• 16-bit resolution
• 64 SE/32 DI multiplex analog input channels
• Up to 500 kSa/s sampling rate
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

DIGITAL OSCILLOSCOPE 4 X 200 MHZ AGILENT DSOX2024A

• 200 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 500KSA/S SIMULTANEOUS AGILENT U2542A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 500 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

AGILENT 6812B AC POWER SOURCE & ANALYZER 750VA

• Power: 750 VA
• Voltage rms: 300 V
• Current rms: 6.5 A
• Repetitive & non-repetitive peak current: 40 A

 

AGILENT N9000A CXA SIGNAL SPECTRUM ANALYZER 9 KHZ..3 GHZ OR 7.5 GHZ

• 9 kHz to 3.0 or 7.5 GHz Frequency range
• 10 MHz (standard), 25 MHz (optional) analysis bandwidth
• Basic EMI precompliance measurement capability available
• Standards-based PowerSuite: channel power, OBW, ACP, CCDF, SEM

 

AGILENT 16821A PORTABLE LOGIC ANALYZER 34 CHANNELS & PATTERN GENERATOR 48 CHANNELS

• 34-channel portable logic analyzer
• 48-channel pattern generator
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 250 MHz State clock rates
• up to 250 Mb/s Data rates
• up to 32 M acquisition memory depth