Seba KMT Easyloc RxTx Pipeline Location and Tracing for Underground Pipes and Cables
• Make optimum preparations for your building work, quickly and reliably
• Avoid cable damage and help to minimise costly accidents and inconvenient delays
• Depth measurement at the push of a button, even without a transmitter
• 33 kHz – compatible with other location systems
• Large display with automatic backlight
• Quick and simple to operate
|
|
|
Seba Teleflex VX Cable Reflectometer for fault location systems
• Range : 20 m … 1280 km
• Bright and large display
• Easiest operation via self guiding and explaining menus
• ARM Slide Technology
• Automatic storage of all results
• Supports all existing prelocation technologies
• Automatic detection and display of cable end and fault position
|
|
|
Seba Teleflex SX Cable Reflectometer for fault location Megger
• ARMslide technology with 15 traces in one ARM shot
• ProRange for optimised display of distant details
• Support of all existing prelocation technologies
• Automatic adjustment and display of cable end and fault
• Compatible with all fault location systems
|
|
|
Seba Teleflex LV Monitor Cable fault location system with monitoring Megger
• Fault location on live low voltage cables
• 3 phase cable monitor for a permanent check of current and voltage
• GSM remote controlled system
|
|
|
Seba Teleflex T3060 Single-Phase Power Cable Reflectometer T 3060
• Range 8 km, 64 km (for ICE and Decay only)
• Fully equipped reflectometer with cursor, gain, and range adjustment
• High-contrast 5.7’’ TFT color display (640 x 480 pixel), with LED backlight
• Single-phase ARM input with ICE, Decay and Trigger
• AC or battery operated (up to 3 hours battery life)
|
|
|
Seba Digiflex Com Reflectometer Fault Locating on Metallic Telecomm Lines, Coaxial and Power Cables
• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use
|
|
|
Seba Easyflex Com Reflectometer Locate Faults on Cu Telecommunication, Signal and Power Cables
• Test range 50 m ... 15000 m
• High local resolution of 5 cm in 50 m test range
• Simple operation due to menu prompting and help functions
• Easy evaluation of the traces by simultaneous display of zoom and total view (split-screen)
• Large display with backlight
• Individual measurement, continuous measurement and averaging
• Measuring connections suitable for live voltage up to 250 V
|
|
|
Seba KMT KMK 8 Communications network cable tester
• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch
|
|
|
Seba Teleflex-VX Adapter for safe operation of reflectometers on overhead lines
• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km
|
|
|
Seba KMT CI LCI Cable Identifier test set
• Inexpensive cable selection system
• Easy to operate
• Safe handling
• Very small
|
|
|
Seba KMT ESG NT Pinpointing Earth Fault Locator in sheath of underground cables
• high accuracy pinpointing of a sheath fault
• Automatic adaptation to voltage level
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• High-contrast color display
|
|
|
Seba KMT Ferrolux FLE 10 Audio Frequency Receiver for Cable Location, Selection, Sheath Faults
• Precise direction guidance with right/left arrows
• “SignalSelect” for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• “DirectSignal” for effective line location
|
|
|
Seba digiPHONE+ Surge wave receiver for acoustic and electromagnetic fault pinpointing in cables
• Perfect acoustic quality and noise immunity
• Automatic mute function to protect your ears
• Bright, transflective sun readable display
• Easiest handling with automatic adjustment
• Earphone volume limitation to 84 dB(A)
|
|
|
Seba digiPHONE+ ESG NT Pinpointing acoustic pinpointing set for steath fault location in underground cables
• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary
|
|
|
Seba KMT HVB-10 10kV Cable Fault Location, Steath Testing and Pinpointing Megger HVB10
• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines
|
|
|
Seba KMT EZ-Thump Cable Fault Location System on LV/MV Cables
• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation
|
|
|
Seba Smart Thump 16 Cable Fault Location System on Low and Medium Voltage Cables
• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7” TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive
|
|
|
Seba SFX 5-1000 SPG 5-1000 Cable Fault Location System on Low and Medium Voltage Cables
• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing
|
|
|
Seba Surgeflex SFX 8-1000 Cable Fault Locating System
• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A
|
|
|
Seba Surgeflex SFX-15 SFX-25 Cable Fault Locating System
• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation
|
|
|
Seba Surgeflex SFX-32 SPG-32 Cable Fault Locating System
• »» DC-testing up to 32 kV
• »» Prelocating
• - Reflection measurement
• - ARM measurement
• (Arc Reflection Method) up to 32 kV
• - Decay up to 32 kV
• - ICE Impulse Current Method
• 0…4 / 8 / 16 / 32 kV
• »» Burning (fault conditioning) up to 32 kV
• »» Cable tracing (optional)
• »» Pinpointing
• - Distance and acoustic measurement
• 0 … 8 / 16 / 32 kV at 1750 J
|
|
|
Seba Surgeflex SFX-40 SPG-40 Cable Fault Locating System
• DC Testing up to 40 kV ARM, ICE and Decay Method integrated
• Operation by VGA Display and single button rotary encoder
• High surge energy fort he acoustic pinpointing 1000 or 2000 J
• Surge voltage levels for MV cablel 0 ... 12,5/25 kV or 0 ... 16/32 kV
• Surge voltage levels for lower voltage 0 ... 3/6 kV or 0 ... 4/8 kV
• Integrated safety system
|
|
|
Seba SWG 500 Surge Wave Generator for Fault Location in Cables SWG500
• Voltage Ranges : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energy : 195J ; 500Joules
• MAx Current Imax : 185mA ; 300mA
• Optimized surge energy for switchable capacitors
• ICE – Impulse Current Method
• ARM – Arc Reflection Method
|
|
|
Seba SWG 505 Surge Wave Generator for Fault Location in Cables SWG505
• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE – Impulse Current Method
• ARM – Arc Reflection Method
|
|
|
Seba SWG 1750 Surge Wave Generator for Fault Location in Cables SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD
• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 – 16 – 32 kV / 1750 J
• SWG 1750 CI with 8 – 16 – 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 – 4 kV / 1150 J and 8 – 16 – 32 kV / 1750 J
• SWG 1750 CD with 8 – 16 – 32 kV / 3500 J
|
|
|
Seba SWG 8-1000 Surge Unit High Voltage Generator for Cable Fault Locating SWG8-1000
• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE – Impulse Current Method
• ARM – Arc Reflection Method
|
|
|
Seba T18/5 Surge Wave Voltage Generator for Cable Fault Locating
• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules
|
|
|
Seba KMT Vivax Metrotech vLoc2 Line Location and Tracer for Underground Pipes and Cables
• Carbon-reinforced plastic housing
• Protection class IP 54 for use in any weather conditions
• Colour display
• High-speed processor
• Several location modes with orientation using a compass
• A large number of available frequencies
• Depth/amperage at the press of a button or sustained
|
|
|
Seba KMT vLocML2 Pipeline Location and Tracing for Underground Pipes and Cables
• Location of passive markers which are used by utility
• companies for labelling underground lines
• Colour-coded display of the signal strength
• Specifi c line location mode
• Specifi c marker location mode
• Mode for simultaneous location of lines and markers
|
|
|
Seba KMT vLoc-5000 Line Location and Tracer for Underground Pipes and Cables
• Precise direction guidance with right/left arrows and guidance compass
• SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
• "Distortion Alert" for signal evaluation
• Internal GPS receiver and data storage
• Permanent depth or signal current intensity measurement
|
|
|
Seba KMT vLoc-9800 Line Location and Tracer for Underground Pipes and Cables
• Clearly laid out user interface
• Automatic or manual amplification options
• Depth and amperage at the press of a button
• Distance Sensitive Left/Right GuidanceTM
• Sheath fault location (optional)
|
|
|
Seba KMT VM-810 Location Underground Pipes and Cables
• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Signal “jumps over” insulating pipe sleeves
|
|
|
Seba KMT VM-850 Location Underground Pipes and Cables
• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Classic design, compact and light
|
|
|
Seba KMT VM-880 Ferrous Metal Locator, Burried and Hidden Assets
• Excellent sensitivity
• Lightweight, just 0.7 kg
• Improved ergonomics for comfort during prolonged usage
• Up to 26 hrs battery life from just 2 x AA (LR6) cells
• Ultra strong, submersible carbon fiber antenna tube
• Dot matrix LCD with backlight
• Audio and visual signal strength indicators
|
|
|
Seba BPS 5000-d Burn and Proof Test System on Medium Voltage Cables BPS-5000d BPS500d BPS 5000d-VLF
• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode
|
|
|
Seba KMT T22/13B Burn Unit for Testing Medium Voltage Cables T22-13B
• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage
|
|
|
Seba KMT BT 500 IS-1 Cable Fault Converter
• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter
|
|
|
Seba KMT OWTS M28 Partial discharge Test and Fault Location System in Cable Insulation
• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan δ - measurement
|
|
|
Seba KMT OWTS M60 Dielectric Diagnosis and Partial Discharge Measuring System
• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight
|
|
|
Seba KMT LPD Monitor On-line PD Partial Discharge Monitoring System for MV and HV
• Portable online PD measuring system for monitoring MV and HV systems
• 16 channels
• Allows effi cient forward planning of necessary maintenance work
• Quick and easy to install
• Integrated automatic knowledge-based evaluation of measured PD levels
• Current status can be viewed at any time via remote access
|
|
|
Seba KMT PD LOC Partial Discharge Pinpointing System for rpecise location of PD faults in medium voltage cables
• Precise PD pinpointing in mixed cable networks
• Location of faults in joints of single core cables
• Easy handling in the field
|
|
|
Seba KMT PD Surveyor Air Partial Discharge Detector for Medium Voltage Cables, Switchgear, Plants
• Three PD sensor technologies in one device
• Early detection of PD activity
• Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
• Directs maintenance resources straight to the problem areas
• Easy to use
|
|
|
Seba KMT TAN DELTA Cable condition Diagnosis System
• Very accurate measurement
• Optional leakage current correction
• High wireless range
• Measurement at high voltage potential
• Light and portable
|
|
|
Seba KMT CDS Cable Diagnostic System for three phase IRC and RVM diagnostics
• Absolutely non-destructive condition evaluation of PE / XLPE / paper-oil insulated cable systems
• Simple operation and automatic measurement procedures
• Three-phase parallel measurement for current and voltage – duration of a complete measurement 1 hour
• Extended dynamic range for IRC measurement for long cable segments
• Measurement of charging current during formation
|
|
|
Seba KMT PVS-100 Phase Identification Tester for Cable Selection
• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money
|
|
|
Seba KMT PIL 8 Phasenlux Phase identification in earthed and short-circuited medium voltage cables
• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification
|
|
|
Seba KMT MFM 10 Cable Steath Fault Location System
• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling
|
|
|
Seba KMT BT 500 IS-1 Cable Fault Converter
• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter
|
|
|
Seba KMT Geolux GL 660-1 Earth fault locator for fault location in isolated, earth free systems
• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to
|
|
|
Seba Fault Sniffer for detection of burning gases from Fault Cables Underground
• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material
|