MEATEST programmable resistance decades resistive resistors decadic boxes

    office@distek.ro     ROM     ENG  
Login | Create account | Forgot password?
Product cart  Products: 0 | Total: 0    
 
 
    Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  How to order? |  Sitemap |  Contact
 
 
Products         [+ Expand]   [- Colapse]

LCR Calibration > MEATEST

 


Precision Programmable Resistance Decade Box Meatest M630

• Resistance range 1.000 00 Ω - 1.200 000 MΩ
• Accuracy 0.003%
• Maximal voltage 200Vpk
• Resolution from 10 μΩ
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally USB, IEEE488, Ethernet

 MEATEST 
 
 
Precision Resistance Decade Box Meatest M622

• Resistance range 1.000 00 Ω - 1.200 000 MΩ
• Accuracy 0.005%
• Resolution from 10 μΩ
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally IEEE488
• Internal ACCU/power line adapter

 MEATEST 
 
 
Resistive Decade Box Meatest M602

• Resistance range from 0.1 Ω to 10 MΩ with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19“ module as option)

 MEATEST 
 
 
RTD Simulator of Temperature Controllers Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 Meatest M612

• Calibration of temperature controllers
• Resistance range from 16 Ω to 10 kΩ
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 MEATEST 
 
 
High Voltage and High Resistance Decade for calibrating Megohmmeters and Insulation Testers up to 10kV Meatest M191

• Total resistance range 10.00 kΩ to 1000.0 GΩ
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 MEATEST 
 
 
AC/DC Resistance Load for calibration of Voltage Sources, Transformers Meatest M192

• Resistance range from 15 Ω to 300 kΩ
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19“ module as option)

 MEATEST 
 
 
LCR Impedance Calibrator of Resistance, Capacitance, Inductance Meatest M550

• Resistance standards from 0.1 Ω to 100 MΩ
• Capacitance standards from 10 pF to 100 μF
• Simulated inductance standards from 10 μH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 MEATEST 
 
 
Capacitance Decade for calibration LCR-Meters Meatest M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 MEATEST 
 
 
High Resistance Decade for calibration of Megohmmeters and Insulation Meters 5kV Meatest M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MΩ – 12 GΩ
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 MEATEST 
 
 
RF Resistance Standard for calibration of LCR Meters Meatest M530

• Resistance range 10 Ω to 1000 Ω
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 MEATEST 
 
 
Resistance Capacitance Inductance Standard for Calibrating LCR-Meters

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 MEATEST 
 


 

Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  Terms and Conditions |  How to order? |  Useful links |  Sitemap |  Contact |  Politica Cookie

        
Copyright © 2010 - 2024 / Distek

Category: MEATEST programmable resistance decades resistive resistors decadic boxes