USB Modular Data Acquisition Unit 16-channels 500kSa/s Agilent U2354A

Code: Agilent U2354A


 

Datasheet PDF, 1.25 Mb

Description

  • High-speed USB 2.0
  • USBTMC-USB488 standard
  • compatible with Microsoft® Windows® operating systems
  • Standalone and modular capabilities
  • 16-bit resolution
  • 16 SE/8 DI multiplex analog input channels
  • Up to 500 kSa/s sampling rate
  • 24-bit programmable TTL input/output channels
  • 2 general purpose digital counter channels
  • Self-calibration capability
 

More products KEYSIGHT

DIGITAL OSCILLOSCOPE 4 X 500 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSO7054B

• 500 MHz bandwidth
• 4 GSa/s sample rate
• 4 analog plus 16 digital channels
• Standard 8 Mpts MegaZoom III deep memory

 

AGILENT U3401A DIGITAL PRECISION MULTIMETER 4.5 DIGIT

• 4.5 digit
• 0.02% DCV accuracy
• 50,000 counts resolution

 

DIGITAL OSCILLOSCOPE 4 X 100 MHZ AGILENT DSOX2014A

• 100 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

PXI SWITCH SPDT MODULE 26-CHANNELS 2A AGILENT M9130A

• General purpose switching to control external devices or
• switch in loads or power supplies
• 26-channel SPDT switch
• 2A switch/carry current
• 60W max power
• Durable, armature relays

 

AGILENT 4263B LCR METER 100 HZ..100 KHZ

• 0.1% basic accuracy
• 100 Hz, 120 Hz, 1 kHz, 10 kHz, 20 kHz, 100 kHz test frequencies
• Measurement parameters: Z, Y, Theta, R, X, G, B, C, L, D, Q, Rdc, N, M

 

PXI MULTIPLEXER MODULE 128-CHANNELS 100V/1A AGILENT M9102A

• 128-channel, high-density 1-wire switch multiplexer
• 100Vrms
• 0.5A/1.0A switch/carry current
• 10W max power
• High-speed 500 usec reed relays

 

USB MODULAR SWITCH MATRIX 4 X 8 AGILENT U2751A

• 32 Two-wire cross points in 4x8 configuration
• DB25 connector
• High-speed USB 2.0 (480MBits/s) TMC488.2 compatible
• Standalone and Modular capabilities

 

AGILENT 34970A DATA ACQUISITION MAINFRAME UNIT 3-SLOT

• 3-slot mainframe
• up to 96 matrix crosspoints
• up to 120 Channels
• 6 1/2-digit (22-bit) internal DMM
• Built-in GPIB and RS-232 interfaces

 

AGILENT N9030A PXA SIGNAL SPECTRUM ANALYZER 3 HZ..3.6 / 8.4 / 13.6 / 26.5 GHZ

• 3 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
• 10 MHz (standard), 25, 40, or 140 MHz analysis bandwidth
• Basic EMI precompliance measurement capability available
• Advanced analysis of more than 70 signal formats

 

AGILENT U2702A USB MODULAR OSCILLOSCOPE 2 X 200 MHZ

• 200 MHz bandwidth
• 2 channels
• 32 Mpts memory depth, 64 Mpts interleaved single-shot
• 1 GSa/s sample rate on 2 channels interleaved, 500 MSa/s each channel