Agilent N5230C PNA-L Microwave Network Analyzer 300 kHz..6/ 13.5/ 20/ 40/ 50 GHz

Code: Agilent N5230C PNA-L


 

Datasheet PDF, 0.99 Mb

Description

  • 300 kHz to 6 GHz, 2-port
  • 300 kHz to 13.5 GHz, available in 2- and 4-port
  • 10 MHz to 20 GHz, available in 2- and 4-port
  • 10 MHz to 40 GHz, 2-port
  • 10 MHz to 50 GHz, 2-port
  • 2- or 4- ports with two built-in sources
  • 110 dB system and 122 dB receiver dynamic range, 32,001 points, 32 channels
  • < .006 dB rms (Option 22x)
  • measurement speed: 4 to 9 µs per point
  • intuitive operation
  • simple interface with pull down menus, hard and soft keys, and online help.
  • 8.4 inch touch screen
 

Standard accessories

 

 

Recommended options

N5230C-010

Time Domain for 13.5, 20, 40, and 50 GHZ PNA-L

N5230C-020

300 kHz to 6 GHz, 2 port, standard test set

N5230C-025

300 kHz to 6 GHz, 2 port, configurable test set and extended power range

N5230C-080

Frequency offset mode

N5230C-082

Scalar calibrated converter measurements

N5230C-120

300 kHz to 13.5 GHz, 2 port, standard test set

N5230C-125

300 kHz to 13.5 GHz, 2 port, configurable test set and extended power range

N5230C-140

300 KHz to 13.5 GHz, 4 port, standard test set

N5230C-145

300 KHz to 13.5 GHz, 4 port, configurable test set and extended power range

N5230C-146

300 KHz to 13.5 GHz, 4 port, configurable test set, extended power range, and internal second source

N5230C-1A7

ISO 17025 compliant calibration

N5230C-1CM

Rackmount kit for installation without handles

N5230C-1CP

Rackmount kit for installation with handles

N5230C-220

10 MHz to 20 GHz, 2 port, standard test set

N5230C-225

10 MHz to 20 GHz, 2 port, configurable test set and extended power range

N5230C-240

300 kHz to 20 GHz, 4 port, standard test set

N5230C-245

300 kHz to 20 GHz, 4 port, configurable test set and extended power range

N5230C-246

300 KHz to 20 GHz, 4 port, configurable test set, extended power range, and internal second source

N5230C-420

10 MHz to 40 GHz, 2 port, standard test set

N5230C-425

10 MHz to 40 GHz, 2 port, configurable test set and extended power range

N5230C-520

10 MHz to 50 GHz, 2 port, standard test set

N5230C-525

10 MHz to 50 GHz, 2 port, configuable test set and extended power range

N5230C-550

Add 4-port measurement application

N5230C-551

Add N-port calibrated measurements for 40 and 50 GHz PNA-L

N5230C-897

Built-in performance test software for Agilent inclusive calibration, perpetual license

N5230C-898

Built-in performance test software for standards compliant calibration, perpetual license

N5230C-A6J

ANSI Z540 compliant calibration

N5230C-UK6

Commercial Calibration Certificate with test data

N5231C-010

Time domain for 6 GHz PNA-L

N5231C-551

Add N-port calibrated measurements for 6, 13.5 and 20 GHz PNA-L

 

More products KEYSIGHT

AGILENT E5071C ENA NETWORK ANALYZER 100 KHZ..4.5/ 6.5/ 8.5/ 14/ 20 GHZ

• Frequency options:
• 9 kHz - 4.5 GHz/ 6.5 GHz/ 8.5 GHz
• 100 kHz - 4.5 GHz/ 6.5 GHz/ 8.5 GHz (with bias tees)
• 300 kHz - 14 GHz/ 20 GHz (with bias tees)

 

AGILENT U2741A MODULAR USB DIGITAL MULTIMETER 5.5 DIGIT

• 5.5 digit
• 0.02% accuracy
• USB PC based Multimeter
• Make fast measurements with up to 100 readings/s

 

AGILENT E4981A CAPACITANCE METER 120 HZ..1 MHZ

• 120 Hz, 1 kHz, 1 MHz measurement frequency
• 0.07% Basic accuracy
• High-speed measurements to 2.3 ms @ 1 MHz

 

DIGITAL OSCILLOSCOPE 2 X 500 MHZ AGILENT DSOX3052A

• 500 MHz bandwidth
• 2 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


AGILENT 81110A 81112A PULSE GENERATOR 330 MHZ

• 1 mHz to 330 MHz
• 1 or 2 Channels(order 2 x 81112A modules)
• 800 ps or 1.6 ns selectable
• Up to 3.8 Vpp into 50 O

 

MULTIPLEXER MODULE 40 CHANNELS AGILENT 34921A

• 40 2-wire channels
• 300V, 1A switch; 2A carry current
• 100 ch/s scanning
• Mix 2- or 4-wire configurations
• 45 MHz Bandwidth

 

PXI MICROWAVE SWITCH MODULE DC-26.5GHZ AGILENT M9157C

• Hybrid Single SP6T Switch Terminated
• Broadband from DC to 26.5 GHz
• Unmatched isolation 90 dB at 12 GHz
• Long life cycles - 2 million cycles guaranteed, 5 million cycles typical

 

PXI RF MATRIX SWITCH 3GHZ 1 X 16, 75 OHM AGILENT M9153A

• RF signal routing to 3 GHz for 75 ohm applications
• 1x16 75 ohm RF switch multiplexer to 3GHz
• 30V, 1A, 10W switching
• 75 ohm input impedance
• 56 dB isolation at 1 GHz

 

AGILENT 16821A PORTABLE LOGIC ANALYZER 34 CHANNELS & PATTERN GENERATOR 48 CHANNELS

• 34-channel portable logic analyzer
• 48-channel pattern generator
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 250 MHz State clock rates
• up to 250 Mb/s Data rates
• up to 32 M acquisition memory depth

 

AGILENT 6060B 6063B DC ELECTRONIC LOAD 250-300W

• Cost-effective for single input applications
• Convenient optional front panel input connection
• 250-300W Power