HIGHTEST TRCAL-10K Turn Ratio Meter Calibrator

Code: TRCAL-10K TRCAL10K


 

Datasheet PDF, 0.87 Mb

Description

The TRCAL-10K is specifically engineered to validate the operational effectiveness of various Electronic Transformer Turns Ratio Testers. Additionally, it serves as a valuable tool for diagnosing issues and providing maintenance services for Turns Ratio Testers. The TRCAL-10K has the capability to accommodate excitation voltages ranging from 1 to 250 Vac, making it compatible with a wide range of turns ratio testers available in the market.

The TRCAL-10K offers a wide range of ratio from 1 to 10,000 (Selection available as follows: 1:1, 2:1, 5:1, 10:1, 50:1, 100:1, 200:1, 500:1, 1,000:1, 2,000:1, 5,000:1, 10,000:1). TRCAL-10K is a light, compact and rugged device with an IP protection class of IP67, (case closed).

Technical Specifications

Ratio Range1 to 10,000
(1:1, 2:1, 5:1, 10:1, 50:1, 100:1, 200:1, 500:1, 1,000:1, 2,000:1, 5,000:1, 10,000:1)

Exciting Voltage Range1 V - 250 V
Exciting WindingsH1-H2 Windings
Dimensions  (318 mm x 257 mm x 152 mm )
Weight3.0 kg
Storage Temperature-30 °C to +70 °C
Humidity95% RH Non-condensing
Protection ClassIP67 (case closed)
Altitude2000m (6562 ft) to fully safety specifications


 

Standard accessories

Included in the package2.5m Standard Ground Cable, Soft Carry Bag
 

More products HIGHTEST

HIGHTEST HARE CONTACT RESITANCE TESTER CIRCUIT BREAKER, SHUNT, DISCONNECTOR

• Portable Contact Resistance Tester
• 0.4A to 100A Adjustable test current (HARE-100)
• 0.4A to 200A Adjustable test current (HARE-200)
• 0.4A to 300A Adjustable test current (HARE-300)
• Up to 5 Ohm resistance measurement
• 0.1 uOhm resolution
• Automatic discharge

 

HIGHTEST TURA-03 TURN RATION TRANSFORMER TESTER TTR

• Turns Ratio Measurement (Single-phase and three-phase measurement)
• Ranges from 0.8 to 50,000 ratio measurement
• High Accuracy (0.08 %)
• 1V, 4V, 10V, 40V, 100V and 250V AC test voltages

 

HIGHTEST TRAN-203 TRANSFORMER ANALYZER FOR TURN RATION AND WINDING RESISTANCE TESTING

• Turns ratio measurement (Single-phase & Three-phase)
• Winding resistance measurement (Single-phase & Three-phase)
• Heat run test/Temperature rise test
• Magnetic Balance Test

 

HIGHTEST SUWI-120 MULTIFUNCTION SUBSTATION TESTER

• Multifunctional test device
• Relay Timing Tests
• Turns Ratio Tests
• Contact Resistance Tests
• 3ph Circuit Breaker Timing Tests

 

HIGHTEST CBSM

• Contact timing channels 6 contact timing channels; Accuracy: 0.01 ms
• CT timing channel 1 CT timing channel, 500 mA, Accuracy: +-0.5 ms
• Digital transducer channels 3 digital transducer channels; Accuracy: 0.02
• V1 voltage channel 20 Vrms
• V2 voltage channel 30 Vdc
• Internal trigger channel 2 A
• External trigger channel 24 Vdc

 

HIGHTEST CIBRE-60 6-CONTACT TIMING CIRCUIT BREAKER ANALYSERS

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 6 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 7TFT Touch Colour Display

 

HIGHTEST CIBRE-30 CIRCUIT BREAKER TESTER ANALYZER

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 3 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 2.28” Built-in Printer
• 7” TFT Touch Colour Display

 

HIGHTEST ARES-200D 200A LOW CONTACT RESISTANCE WITH DYNAMIC AND STATIC RESISTANCE MEASUREMENT

• ontact resistance measurement
• Adjustable current: 1 A to 200 A
• Measurement range from 0.1 µOhm to 5 Ohm
• Typical accuracy 0.1%
• Static resistance measurement
• Dynamic resistance measurement
• Dual ground test mode

 

HIGHTEST WINRES-20 WINDING RESISTANCE OHMMETER TESTER

• 2-channel resistance measurement
• Measurements from 0.1 uOhm to 100,000 Ohm
• 0.001 A to 20 A DC adjustable current output
• High accuracy (0.1%)
• Test Voltage 50 V
• Demagnetisation feature

 

HIGHTEST TURA-01 TRANSFORMER TURN RATIO TESTER

• Turns Ratio Measurement (Single-phase and three-phase measurement)
• Ranges from 0.8 to 33,000 Ratio Measurement
• High Accuracy (0.08 %)
• 1V, 4V, 10V, 40 V and 100 V AC Test Voltages