Brand: HART SCIENTIFIC

Metrology Thermometer Calibration Well -30°C..155°C Hart Scientific 9171

Code: Hart Scientific 9171


 

Datasheet PDF, 0.3 Mb

Description

  • -30 °C to 155 °C temperature range
  • ± 0.005 °C stability
  • Best-performing industrial heat sources (accuracy, stability, uniformity) in the world 
  • Immersion depth to 203 mm (8 in) 
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C 
 

More products HART SCIENTIFIC

FIELD DRY WELL TEMPERATURE CALIBRATOR 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability

 

THERMOCOUPLE FURNACE CALIBRATOR 300°C..1100°C HART SCIENTIFIC 9112B

• 300 °C to 1100 °C temperature range
• Combined stability and uniformity better than ±0.4°C
• RS-232 serial interface standard
• High capacity for simultaneous comparison calibrations

 

INFRARED TEMPERATURE CALIBRATOR 50°C/ 100°C/ 150°C HART SCIENTIFIC 9135

• Fast and easy IR calibrations
• Three temperatures available: 50 °C, 100 °C, and 150 °C
• NIST-traceable calibration included

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 35°C..350°C HART SCIENTIFIC 9140

• 35 °C to 350 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.03 °C stability

 

PORTABLE LAB CALIBRATION DRY WELL -40°C..140°C HART SCIENTIFIC 9007

• Designed for on-ship and on-the-go lab applications
• Covers -40 °C to 140 °C
• Includes three-inch and six-inch calibration zones


FIELD METROLOGY TEMPERATURE CALIBRATION WELL -25°C..150°C HART SCIENTIFIC 9142

• -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.01 °C

 

TEMPERATURE CALIBRATION OIL MICRO-BATH -30°C..125°C HART SCIENTIFIC 7103

• -30 °C to 125 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.03°C

 

DUAL INDUSTRIAL TEMPERATURE CALIBRATION BLOCK -15°C..350°C HART SCIENTIFIC 9009

• Temperatures from -15 °C to 350 °C in one unit
• 50 °C to 350 °C Hot block, ± 0.6 °C Accuracy
• -15 °C to 110 °C Cold Block, ± 0.2 °C Accuracy
• ± 0.05 °C Stability

 

SURFACE SENSOR CALIBRATOR 35°C..400°C HART SCIENTIFIC 3125

• Calibrates surface sensors up to 400°C
• Uses Hart 2200 Controller for excellent accuracy and stability
• NIST-traceable calibration included

 

METROLOGY THERMOMETER CALIBRATION WELL 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world