Brand: FLUKE BIOMEDICAL

Infusion Analyzer Pump Tester Fluke Biomedical IDA 4 Plus

Code: Fluke Biomedical IDA 4 Plus


 

Datasheet PDF, 1.1 Mb
     

Description

Overview

IDA 4 Plus Infusion Device Analyzer is your solution to concerns about infusion pump preventive maintenance and repair. This digital infusion pump tester uses fundamental measurement technology integrated with sophisticated electronics to ensure accuracy and reduce risk of human error during infusion pump testing. The IDA 4 Plus infusion pump analyzer maximizes productivity by testing up to four infusion pumps or channels at once, allowing you to move on to other tasks while letting the IDA 4 Plus takes care of infusion pump testing and documentation.

The IDA 4 Plus Infusion Device Analyzer tests virtually any brand of infusion pump including Alaris® (Carefusion), Hospira, Baxter, Abbott, Sigma and many others. The IDA 4 Plus infusion pump tester is compatible with a wide array of infusion pumps including syringe pumps, volumetric pumps and anesthesia pumps. The infusion device tester measures instantaneous flow, average flow, occlusion pressure, and analyzes patient-control analgesia (PCA) units. An optional PCA trigger box provides automated PCA pump control, allowing technicians to set up tests and walk away. An autostart feature simplifies syringe pump testing or other tests that have long startup times.

With built-in memory, the IDA 4 Plus infusion device tester records infusion pump test results internally and provides easy-to-read test-result graphs live right on the analyzer’s screen. The display is so large numbers can be read from across the room. Additionally, the IDA 4 Plus infusion pump analyzer comes with Hydrograph PC software for creating full-color graphs and reports. For automated infusion pump testing, the IDA 4 Plus is compatible with Fluke Biomedical’s medTester 5000C (US only).

The IDA 4 Plus Infusion Device Analyzer comes in 1-2-3- or 4-channel configurations. This allows the option of adding up to three channels to your infusion pump analyzer at a later time to meet the evolving needs of your work group.

Test any parameter you need with confidence with the world’s most trusted infusion pump tester.

 

 

  • Tests up to four infusion pumps simultaneously
  • Compatible with virtually any type of infusion device
  • Instantaneous and average flow measurement
  • Occlusion pressure measurements to 45 psi
  • Single- and dual-flow (piggyback) testing
  • Full PCA testing (bolus volume, lockout time, and automated external triggering)
  • Autostart mode enables unit to begin testing only when fluid is detected
  • Live graphical view for real real-time pump malfunction/problem alerts or analysis
  • Built-in memory to save test results for printing or downloading to computer
  • Hydrograph results-reporting software to display, store and recall results via PC
  • Automated testing through Fluke Biomedical medTester 5000C (US only) and IDA 4 Ansur Plug-In
  • Ability to add up to three channels for multiple, simultaneous infusion pump testing
  • Ability to create trumpet curves and test up to 12 channels simultaneously with the IDA 4 Ansur Plug-In
 

Standard accessories

  • Electronic User Manual and HydroGraph software (48459)
  • 20 ml Priming Syringe (49964)
  • Luerlock-3 Way (one for each channel) (48457FG)
  • 5’ Plastic Drain Line (76044)
  • Power cord (country specific)
  • Serial Communication Cable (75029)
 

More products FLUKE BIOMEDICAL

RIGID ENDOSCOPE TESTER FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required


ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


GAS/ LIQUID PRESSURE TESTER OF MEDICAL EQUIPMENTS FLUKE BIOMEDICAL DPM2PLUS

• Handheld
• Battery operated
• 1 % accuracy
• Five selectable scale ranges
• Voltage output to drive a recorder for assessing electronics of pressure measurement circuit
• Air or liquid measurement


AIR GAS FLOW ANALYZER FLUKE BIOMEDICAL VT PLUS HF

• Bi-directional flow, pressure, volume, and oxygen concentration, and pressure measurements
• Low- and high-pressure, and flow measurement capability
• Special HF mode-up to 900 BPM (15 Hz)
• RS-232 and printer ports
• Included Windows-compatible graphics software

 

ION CHAMBER SURVEY METER FOR BETA, GAMMA, X-RAY RADIATION FLUKE BIOMEDICAL 451B

• High sensitivity measurement of rate and dose simultaneously, with the capability to record peak rate
• Auto-ranging and auto-zeroing
• RS-232 communications interface with optional Windows-based Excel add-in for data logging
• Ergonomic, anti-fatique handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm

 

DEFIBRILLATOR PULSE EXTERNAL PACER ANALYZER FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


NEUTRON SURVEY METER MONITOR FLUKE BIOMEDICAL190N

• Auto-scaling measurement of rate and dose (integrate mode includes dose and time accumulation)
• True Rem readings recorded across a wider (lower and higher) rate range
• Ergonomic, portable design: adjustable shoulder strap and rugged handle with padded grip
• Flexible detector assembly, 190 can be removed for remote readings
• Available in SI units


HANDHELD ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

INCUBATOR ANALYZER FLUKE BIOMEDICAL INCU

• Portability (sitting in place of infant within incubator)
• Single-instrument measurement and documentation for key infant-incubator parameters
• Measurement for most parameters according to IEC and AAMI standards
• Time-saving in testing critical infant incubators
• Windows® software for evaluation and documentation
• Numerical and graphical reports