  • 100 MHz bandwidth
  • 4 analog channels plus 16 digital channels
  • 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode
  • Largest screen in its class: 8.5-inch WVGA display
  • Fastest update rate of 1,000,000 waveforms per second
  • Deepest memory: 4 Mpts
  • Best-in-class oscilloscope
  • Integrated logic timing analyzer (MSO)
  • Only built-in 20-MHz function generator: WaveGen
  • Only hardware-based protocol analyzer
  • Upgradability: add bandwidth, digital channels, or WaveGen after purchase
  • Optional serial protocol analysis applications including: I²C, SPI, RS232, UART, CAN, LIN, and I²S
  • Segmented memory
  • Mask Testing
 

Standard accessories

  • 4 x N2862B Passive probe 150 MHz 10:1 attenuation
  • N6450-60001 16 digital channel MSO probe
  • Calibration Certificate
  • Power Cord
  • Software
  • Manual
 

Recommended options

Options

 

DSOX3BW24

Bandwidth upgrade from 100 MHz to 200 MHz

DSOX3WAVEGEN

WaveGen (built-in function generator)

DSOX3MSO

MSO Upgrade: upgrades your 3000 X-Series scope to 16 digital timing channels

DSOX3MEMUP

Memory Upgrade: 4 Mpts half-channel

DSOXEDK

Educator"™s kit

DSOX3MASK

Mask testing

DSOX3SGM

Segmented memory

DSOX3EMBD

Embedded serial triggering and analysis (I2C, SPI)

DSOX3COMP

Computer serial triggering and analysis (RS232/422/485/UART)

DSOX3AUTO

Automotive serial triggering and analysis (CAN, LIN)

DSOX3AUDIO

Audio serial triggering and analysis (I2S)

U1881A

Power measurement and analysis

B4610A

PC offline viewing

 

Recommended Probes

 

N2889A

350 MHz passive probe 10:1/1:1 switchable attenuation

10076A

250 MHz 100:1, 4 kV high-voltage passive probe

N2771B

passive probe 50 MHz 1000:1 attenuation

N2795A

single-ended active probe 1 GHz ±8 V with AutoProbe interface

N2790A

differential active probe 100 MHz ±1.4 kV with AutoProbe interface

N2792A

differential active probe 200 MHz ±20V

N2793A

differential active probe 800 MHz ±15V

1146A

100 kHz, 100 A, AC/DC current probe

1147A

AC/DC current probe 50 MHz 15 A with AutoProbe interface

N2893A

AC/DC current probe 100 MHz 15 A with AutoProbe interface

 

Recommended Accessories

 

DSOXLAN

LAN/VGA connection module

DSOXGPIB

GPIB connection module

N6456A

Rack mount kit

N6457A

Soft carrying case and front panel cover

N6458A

Hard copy manual

 

 

More products Agilent 3000X 100-500MHz

AGILENT 34410A DIGITAL PRECISION MULTIMETER 6.5 DIGIT

• 6 ½ digit resolution
• Basic accuracy: .0030 % DC,0.06% AC
• 14 measurement functions including capacitance & temperature
• Data Logger with 50,000 reading non-volatile memory

 

AGILENT E3631A E3632A E3633A E3634A DC PROGRAMMABLE POWER SUPPLIES 80-200W

• Single and triple output
• 80 W to 200 W output power
• Low noise and excellent regulation
• GPIB and RS-232 standard

 

AGILENT N9000A CXA SIGNAL SPECTRUM ANALYZER 9 KHZ..3 GHZ OR 7.5 GHZ

• 9 kHz to 3.0 or 7.5 GHz Frequency range
• 10 MHz (standard), 25 MHz (optional) analysis bandwidth
• Basic EMI precompliance measurement capability available
• Standards-based PowerSuite: channel power, OBW, ACP, CCDF, SEM

 

AGILENT U2702A USB MODULAR OSCILLOSCOPE 2 X 200 MHZ

• 200 MHz bandwidth
• 2 channels
• 32 Mpts memory depth, 64 Mpts interleaved single-shot
• 1 GSa/s sample rate on 2 channels interleaved, 500 MSa/s each channel


HAND HELD MULTIMETER PROCESS CALIBRATOR AGILENT U1401B

• Dual display with bright LCD backlight
• 4-20 mA and 0-20 mA percentage scale readout
• 50,000 count true-RMS DMM
• Simultaneous signal source and measure

 

AGILENT 81104A 81105A PULSE GENERATOR 80 MHZ

• 1 mHz to 80 MHz
• 1 or 2 Channels(order 2 x 81105A modules)
• 3 ns to 200 ms variable transition time
• Up to 10 Vpp into 50 O (20 Vpp into open circuit)

 

AGILENT 1602B HAND HELD DIGITAL OSCILLOSCOPE 2 X 20 MHZ

• 20 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 125KS Maximum recording length viewable on screen with zoom function

 

AGILENT E4980A PRECISION LCR METER 20 HZ..2 MHZ

• 20 Hz to 2 MHz
• 4-digit resolution in any range
• 0.05% basic accuracy
• Measurement parameters: |Z|, |Y|, ?, R, X, G, B, L, C, D, Q, Rdc, Idc, Vdc
• High-speed measurements up to 5.6 ms

 

AGILENT 53230A RF UNIVERSAL FREQUENCY COUNTER 12 DIGIT 2 CH 350 MHZ

• 2 x 350 MHz baseband frequency
• 12 digits/sec resolution
• 6 or 15 GHz optional microwave channels
• 20 ps single-shot time resolution

 

DIGITAL OSCILLOSCOPE 2 X 100 MHZ AGILENT DSOX2012A

• 100 MHz bandwidth
• 2 analog channels
• 1GSa/s per channel sample rate